Uni-Trend UT58A Spécifications

Naviguer en ligne ou télécharger Spécifications pour Multimètres Uni-Trend UT58A. Uni-Trend UT58B multimeter Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 36
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
1
Table of Contents
Title Page
Overview
Unpacking Inspection
Safety Information
Rules For Safe Operation
International Electrical Symbols
The Meter Structure
Rotary Switch
Functional Buttons
Display Symbols
Measurement Operation
A. DC and AC Voltage Measurement
B. DC and AC Current Measurement
C. Measuring Resistance
D. Measuring Diodes
E. Testing for continuity
F. Capacitance measurement
G. Temperature Measurement
(UT58B/UT58C only)
H. Measuring Transistor
I. Frequency Measurement (UT58C only)
Sleep Mode
Operation of Hold Mode
General Specifications
Accuracy Specifications
A. DC Voltage
B. AC Voltage
C. DC Current
D. AC Current
E. Resistance Test
F. Diodes Test
G. Continuity Test
H. Capacitance
I. Temperature (UT58B/UT58C only)
J. Transistor Test
3
10
4
11
12
14
14
15
17
18
20
21
22
23
24
24
25
26
27
27
27
28
28
29
29
29
30
30
31
5
6
8
9
Model UT58A/B/C: OPERATING MANUAL
Vue de la page 0
1 2 3 4 5 6 ... 35 36

Résumé du contenu

Page 1 - Table of Contents

1Table of ContentsTitle PageOverviewUnpacking InspectionSafety InformationRules For Safe OperationInternational Electrical S

Page 3 - Overview

Functional ButtonsBelow table indicated for information about the functionalbutton operations.POWER(YellowButton)Turn the Meter on and off.l Press dow

Page 4 - Unpacking Inspection

Turn the Meter on and off.l Press down the POWER to turn on the Meter.l Press up the POWER to turn off the Meter.No. Symbol

Page 5 - Safety Information

µA, mA, ANo. Symbol Meaning9Ω,kΩ,MΩmV, VµF nFoCModel UT58A/B/C: OPERATING MANUAL13

Page 6 - Rules For Safe Operation (1)

black red(figure 3)WarningTo avoid harms to you or damages to the Meter fromelectric shock, please do not attempt to measurevoltages higher than 10

Page 7 - Rules For Safe Operation (2)

black red(figure 4)To measure DC or AC Voltage, connect the Meter as follows:1. Insert the red test lead into the HzVΩ (UT58C) or VΩ

Page 8

Use proper terminals, function, and range for themeasurement. When the testing leads are connectedto the current terminals, do not parallel them acros

Page 9 - 5. POWER

Measurement Operation(4)WarningTo avoid damages to the Meter or to the devicesunder test, disconnect circuit power and dischargeall the high-voltage c

Page 10

Measurement Operation(4)The resistance ranges are:Model UT 58A/UT58B:200Ω, 2kΩ, 20kΩ, 2MΩ,20MΩ and200MΩ.Model UT 58C:200Ω, 2kΩ, 20kΩ, 2MΩ and 20MΩ.1.

Page 11 - Functional Buttons

WarningTo avoid damage to the Meter or to the equipmentunder test, disconnect circuit power and dischargeall high-voltage capacitors before measuring

Page 12

Title Page K. Frequency (UT58C only)Maintenance A. General Servic

Page 13

Use the diode test to check diodes, transistors, and othersemiconductor devices. The diode test sends a currentthrough the semiconductor junction, an

Page 15 - Measurement Operation(2)

(figure 9)9Model UT58A/B/C: OPERATING MANUAL 22

Page 16 - Measurement Operation(3)

Model UT58A/B/C: OPERATING MANUAL23

Page 17 - Measurement Operation(4)

POWERModel UT58A/B/C: OPERATING MANUAL24

Page 18

Model UT58A/B/C: OPERATING MANUAL25

Page 19

General SpecificationsMaximum Voltage or Current between input Terminals andGrounding: According to different functional input protectionvalue.l Fuse

Page 20 - Measurement Operation(7)

General SpecificationsMaximum Voltage or Current between input Terminals andGrounding: According to different functional input protectionvalue.l Fuse

Page 21

Accuracy Specifications(2)C. DC CurrentRemarks:l At 20A Range: For continuous measurement 10 seconds and interval time between 2 measurement great

Page 22 - (figure 9)

UT58ABCUT58ABCUT58ABCUT58ABCUT58ABCUT58AB

Page 23

OverviewWarningTo avoid electric shock or personal injury, read the“Safety Information” and “Rules for Safety Operation”carefully before using the Met

Page 24

H. CapacitanceAccuracy Specifications(4)±(5.0%+4)When it is 40µF: the obtainedreading is only for reference2nF 1pF200nF 0.1nF100µF

Page 25

±(5.0%+4)When it is 40µF: the obtainedreading is only for referenceAccuracy Specifications(5)J. Transistor testRange ResolutionAccuracy±(a% reading

Page 26

±(1.5%+5) 250V ACMaintenance(1)This section provides basic maintenance informationincluding battery and fuse replacement instruction.WarningD

Page 27 - Accuracy Specifications(1)

To replace the Meter’s fuse:1. Turn the Meter off and remove all connections from the terminals.2. Remove the holster from the Meter.3. Remove

Page 28 - Accuracy Specifications(2)

To replace the Meter’s fuse:1. Turn the Meter off and remove all connections from the terminals.2. Remove the holster from the Meter.3. Remove

Page 29

Model UT58A/B/C: OPERATING MANUAL35

Page 30 - Accuracy Specifications(4)

Copyright 2001 Uni-Trend Group Limited.All rights reserved.Manufacturer:Uni-Trend Technology (Dongguan) LimitedDong Fang Da DaoBei Shan Dong Fang Indu

Page 31 - Accuracy Specifications(5)

Unpacking InspectionIn the event you find any missing or damage, pleasecontact your dealer immediately.1 English Operating Manual2 Test Lead3

Page 32 - Maintenance(1)

Safety InformationThis Meter complies with the standards IEC61010: inpollution degree 2, overvoltage category (CAT. II 1000V,CAT. III 600V) and double

Page 33 - Maintenance(2)

WarningTo avoid possible electric shock or personal injury,and to avoid possible damage to the Meter or to theequipment under test, adhere to the foll

Page 34

Rules For Safe Operation (2)l When using the test leads, keep your fingers behind the finger guards.l Disconnect circuit power and discharge all

Page 35

International Electrical SymbolsAC (Alternating Current).DC (Direct Current).Grounding.Double Insulated.Deficiency of Built-In Battery.Warning. Refer

Page 36

(figure 1)The Meter Structure (see figure 1)1. LCD Display.2. HOLD Button.3. Rotary Switch.4. Input Terminals.5. POWERModel UT58A/B/C: OPERATING